Numbers, data, facts.
Measurement recording and processing with the GLD 202 Leak Detector.
Signal and frequency analysis
- analog range limits 10-50,000 Hz
- digital sampling rate 128,000 samples per second
- data compression of the relevant measurement data to 1 kilobyte/second
- multi-channel spectral analyses
- Fast Fourier Transform (FFT) from 50Hz-50kHz
- transient recognition with classification, window width 2 ms
- recognition of marker signals in noise
- integral of the energy from 20-40kHz (results like the MLD 201)
- average value over 1000ms (100 measurements)
- peak values in 35kHz and 72Hz channels to identify markers
- virtual marker recognition

- Analog measurement processing
Pressure
- recording with piezoresistive sensor
- recording of the pipeline pressure 0 to 80 bar (atmospheres, 0 to 1176 psi)
- resolution 10 bits, < 0.1 bar (atmospheres, <1.8 psi)
- measurement accuracy 1%
Temperature
- temperature of the medium: 0 to 40/50°C (32 to 130-148°F)
- resolution 10 bits, < 0.1°C (0.2°F)
- measurement accuracy 1%
Time
- date and time
- resolution 1 sec

- Digital measurement processing
Distance
- counting the signal impulses from the optional odometer
- two separate channels
- recognition of the direction of travel
- resolution <1m (3.3ft)
Battery life
- Monitoring of the charge and discharge, auto-matic switching to sleep mode when batteries are discharged.
Storage of measured values
- Currently on digital camera-type SD (Secure Digital) card, with a capacity limited only by card size (recording duration more than 200 hours)